Librería: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Alemania
Taschenbuch. Condición: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Bulk power transfer by a vast expanded electrical power transmission network demands robustness and ability to withstand both internal and external adverse conditions that maybe experienced by the power transmission network. Therefore, the insulation of equipment, to be used in the power system, should be reliable enough to withstand these adverse conditions. To gauge the strength of the insulation used in power equipment or to understand the reasons of its failure, mathematical calculations are carried out to determine the transfer function of power equipment, which can be used for diagnosis in case of malfunctioning. Various factors affecting the testing setup and power equipment are taken into consideration. The results of mathematical calculations are compared with OrCAD PSpice & Wolfram Mathematica simulations to verify the integrity of mathematical technique proposed to determine the transfer function of a given power equipment. Transformer is used as power equipment in this research for the development technique for determination of transfer function. 92 pp. Englisch. Nº de ref. del artículo: 9783659451102
Cantidad disponible: 2 disponibles
Librería: Books Puddle, New York, NY, Estados Unidos de America
Condición: New. Nº de ref. del artículo: 26396996046
Cantidad disponible: 4 disponibles
Librería: moluna, Greven, Alemania
Condición: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Arshad Muhammad UmerMuhammad Umer Arshad did his B.Sc. & M.Sc., in Electrical Engineering in 2005 & 2012 respectively, from University of Engineering & Technology, Lahore, Pakistan. He is now serving as a Lecturer in the Department o. Nº de ref. del artículo: 385766921
Cantidad disponible: Más de 20 disponibles
Librería: Majestic Books, Hounslow, Reino Unido
Condición: New. Print on Demand. Nº de ref. del artículo: 400429585
Cantidad disponible: 4 disponibles
Librería: Biblios, Frankfurt am main, HESSE, Alemania
Condición: New. PRINT ON DEMAND. Nº de ref. del artículo: 18396996036
Cantidad disponible: 4 disponibles
Librería: buchversandmimpf2000, Emtmannsberg, BAYE, Alemania
Taschenbuch. Condición: Neu. Neuware -Bulk power transfer by a vast expanded electrical power transmission network demands robustness and ability to withstand both internal and external adverse conditions that maybe experienced by the power transmission network. Therefore, the insulation of equipment, to be used in the power system, should be reliable enough to withstand these adverse conditions. To gauge the strength of the insulation used in power equipment or to understand the reasons of its failure, mathematical calculations are carried out to determine the transfer function of power equipment, which can be used for diagnosis in case of malfunctioning. Various factors affecting the testing setup and power equipment are taken into consideration. The results of mathematical calculations are compared with OrCAD PSpice & Wolfram Mathematica simulations to verify the integrity of mathematical technique proposed to determine the transfer function of a given power equipment. Transformer is used as power equipment in this research for the development technique for determination of transfer function.Books on Demand GmbH, Überseering 33, 22297 Hamburg 92 pp. Englisch. Nº de ref. del artículo: 9783659451102
Cantidad disponible: 2 disponibles
Librería: AHA-BUCH GmbH, Einbeck, Alemania
Taschenbuch. Condición: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Bulk power transfer by a vast expanded electrical power transmission network demands robustness and ability to withstand both internal and external adverse conditions that maybe experienced by the power transmission network. Therefore, the insulation of equipment, to be used in the power system, should be reliable enough to withstand these adverse conditions. To gauge the strength of the insulation used in power equipment or to understand the reasons of its failure, mathematical calculations are carried out to determine the transfer function of power equipment, which can be used for diagnosis in case of malfunctioning. Various factors affecting the testing setup and power equipment are taken into consideration. The results of mathematical calculations are compared with OrCAD PSpice & Wolfram Mathematica simulations to verify the integrity of mathematical technique proposed to determine the transfer function of a given power equipment. Transformer is used as power equipment in this research for the development technique for determination of transfer function. Nº de ref. del artículo: 9783659451102
Cantidad disponible: 1 disponibles
Librería: preigu, Osnabrück, Alemania
Taschenbuch. Condición: Neu. Transfer Function Investigation Using Multi-Stage HV Impulse Generator | Transfer Function Investigation of Power Equipment Using Multi-Stage High Voltage Impulse Generator | Muhammad Umer Arshad (u. a.) | Taschenbuch | 92 S. | Englisch | 2013 | LAP LAMBERT Academic Publishing | EAN 9783659451102 | Verantwortliche Person für die EU: BoD - Books on Demand, In de Tarpen 42, 22848 Norderstedt, info[at]bod[dot]de | Anbieter: preigu. Nº de ref. del artículo: 113818775
Cantidad disponible: 5 disponibles