Phasor measurement units (PMUs) are considered as a promising tool for future monitoring, protection and control of power systems. One of the applications of phasor measurements is state estimation. The first step in state estimation is to gather measured data from different substations in a power network. These measurements must be sufficient to make the system observable. This book adopts three algorithms for minimizing the size of the PMU configuration while allowing full observability of the network; Depth First Search (DFS), Simulated Annealing (SA) and Minimum Spanning Tree (MST) algorithms. The applied methodologies included the system observablility during normal operating conditions, as well as single branch forced outages in order to obtain a reliable system. The book also adopts two efficient heuristic techniques for optimal PMU placement; Greedy algorithm and Single Vertex Algorithm. To verify the effectiveness of the introduced algorithms, comparative studies are conducted on four test systems with encouraging results. The obtained results are compared with the results of other approaches from literature to demonstrate the effectiveness of the applied methods.
"Sinopsis" puede pertenecer a otra edición de este libro.
Phasor measurement units (PMUs) are considered as a promising tool for future monitoring, protection and control of power systems. One of the applications of phasor measurements is state estimation. The first step in state estimation is to gather measured data from different substations in a power network. These measurements must be sufficient to make the system observable. This book adopts three algorithms for minimizing the size of the PMU configuration while allowing full observability of the network; Depth First Search (DFS), Simulated Annealing (SA) and Minimum Spanning Tree (MST) algorithms. The applied methodologies included the system observablility during normal operating conditions, as well as single branch forced outages in order to obtain a reliable system. The book also adopts two efficient heuristic techniques for optimal PMU placement; Greedy algorithm and Single Vertex Algorithm. To verify the effectiveness of the introduced algorithms, comparative studies are conducted on four test systems with encouraging results. The obtained results are compared with the results of other approaches from literature to demonstrate the effectiveness of the applied methods.
She received her B.SC and M.SC degrees in electrical engineering from Faculty of Engineering, Ain Shams University, Egypt in 2007, 2013 respectively. Currently she is working at the Higher Institute of Engineering and Technology, Fifth Settlement, Cairo, Egypt. Her research interests include applications of optimization techniques to power systems.
"Sobre este título" puede pertenecer a otra edición de este libro.
Librería: PBShop.store US, Wood Dale, IL, Estados Unidos de America
PAP. Condición: New. New Book. Shipped from UK. THIS BOOK IS PRINTED ON DEMAND. Established seller since 2000. Nº de ref. del artículo: L0-9783659438462
Cantidad disponible: Más de 20 disponibles
Librería: PBShop.store UK, Fairford, GLOS, Reino Unido
PAP. Condición: New. New Book. Delivered from our UK warehouse in 4 to 14 business days. THIS BOOK IS PRINTED ON DEMAND. Established seller since 2000. Nº de ref. del artículo: L0-9783659438462
Cantidad disponible: Más de 20 disponibles
Librería: Ria Christie Collections, Uxbridge, Reino Unido
Condición: New. In. Nº de ref. del artículo: ria9783659438462_new
Cantidad disponible: Más de 20 disponibles
Librería: Chiron Media, Wallingford, Reino Unido
Paperback. Condición: New. Nº de ref. del artículo: 6666-IUK-9783659438462
Cantidad disponible: 10 disponibles
Librería: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Alemania
Taschenbuch. Condición: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Phasor measurement units (PMUs) are considered as a promising tool for future monitoring, protection and control of power systems. One of the applications of phasor measurements is state estimation. The first step in state estimation is to gather measured data from different substations in a power network. These measurements must be sufficient to make the system observable. This book adopts three algorithms for minimizing the size of the PMU configuration while allowing full observability of the network; Depth First Search (DFS), Simulated Annealing (SA) and Minimum Spanning Tree (MST) algorithms. The applied methodologies included the system observablility during normal operating conditions, as well as single branch forced outages in order to obtain a reliable system. The book also adopts two efficient heuristic techniques for optimal PMU placement; Greedy algorithm and Single Vertex Algorithm. To verify the effectiveness of the introduced algorithms, comparative studies are conducted on four test systems with encouraging results. The obtained results are compared with the results of other approaches from literature to demonstrate the effectiveness of the applied methods. 116 pp. Englisch. Nº de ref. del artículo: 9783659438462
Cantidad disponible: 2 disponibles
Librería: Books Puddle, New York, NY, Estados Unidos de America
Condición: New. pp. 116. Nº de ref. del artículo: 26126734412
Cantidad disponible: 4 disponibles
Librería: moluna, Greven, Alemania
Condición: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Salem Reham H.She received her B.SC and M.SC degrees in electrical engineering from Faculty of Engineering, Ain Shams University, Egypt in 2007, 2013 respectively. Currently she is working at the Higher Institute of Engineering and T. Nº de ref. del artículo: 5156265
Cantidad disponible: Más de 20 disponibles
Librería: Majestic Books, Hounslow, Reino Unido
Condición: New. Print on Demand pp. 116 2:B&W 6 x 9 in or 229 x 152 mm Perfect Bound on Creme w/Gloss Lam. Nº de ref. del artículo: 133853075
Cantidad disponible: 4 disponibles
Librería: Biblios, Frankfurt am main, HESSE, Alemania
Condición: New. PRINT ON DEMAND pp. 116. Nº de ref. del artículo: 18126734406
Cantidad disponible: 4 disponibles
Librería: buchversandmimpf2000, Emtmannsberg, BAYE, Alemania
Taschenbuch. Condición: Neu. This item is printed on demand - Print on Demand Titel. Neuware -Phasor measurement units (PMUs) are considered as a promising tool for future monitoring, protection and control of power systems. One of the applications of phasor measurements is state estimation. The first step in state estimation is to gather measured data from different substations in a power network. These measurements must be sufficient to make the system observable. This book adopts three algorithms for minimizing the size of the PMU configuration while allowing full observability of the network; Depth First Search (DFS), Simulated Annealing (SA) and Minimum Spanning Tree (MST) algorithms. The applied methodologies included the system observablility during normal operating conditions, as well as single branch forced outages in order to obtain a reliable system. The book also adopts two efficient heuristic techniques for optimal PMU placement; Greedy algorithm and Single Vertex Algorithm. To verify the effectiveness of the introduced algorithms, comparative studies are conducted on four test systems with encouraging results. The obtained results are compared with the results of other approaches from literature to demonstrate the effectiveness of the applied methods.VDM Verlag, Dudweiler Landstraße 99, 66123 Saarbrücken 116 pp. Englisch. Nº de ref. del artículo: 9783659438462
Cantidad disponible: 1 disponibles