Flexible alternating current transmission system (FACTS) and multi-line FACTS controllers play an important role in electrical power transmission systems by improving power quality and increasing power transmission capacity. These controllers are nonlinear and highly complex. Therefore, during transient conditions, it is very difficult to use conventional time and frequency domain techniques alone to determine the precise dynamic behavior of the harmonics introduced into the system by these controllers. In particular, the time-varying nature of the harmonic components is not captured by these techniques. This book consists of new dynamic models for seven important and popular FACTS controllers using a technique called the dynamic harmonic domain method. These models are more accurate than existing models. The models were simulated in the presence of disturbances to show the evolution in time of the harmonic coefficients and power quality indices. This detailed information about dynamic harmonic response is useful for power quality assessment and can be used as a tool for analyzing the system under the steady state and transient conditions and designing better control circuits.
"Sinopsis" puede pertenecer a otra edición de este libro.
Flexible alternating current transmission system (FACTS) and multi-line FACTS controllers play an important role in electrical power transmission systems by improving power quality and increasing power transmission capacity. These controllers are nonlinear and highly complex. Therefore, during transient conditions, it is very difficult to use conventional time and frequency domain techniques alone to determine the precise dynamic behavior of the harmonics introduced into the system by these controllers. In particular, the time-varying nature of the harmonic components is not captured by these techniques. This book consists of new dynamic models for seven important and popular FACTS controllers using a technique called the dynamic harmonic domain method. These models are more accurate than existing models. The models were simulated in the presence of disturbances to show the evolution in time of the harmonic coefficients and power quality indices. This detailed information about dynamic harmonic response is useful for power quality assessment and can be used as a tool for analyzing the system under the steady state and transient conditions and designing better control circuits.
Bharat Vyakaranam received his B.S. and M.S degrees in the from the Jawaharlal Nehru Technological University and his Ph.D. degree from the Cleveland State University. F. Eugenio Villaseca received his BS from Universidad Tecnica Federico Santa Maria, his MS from the University of Notre Dame and Ph.D from Arizona State University.
"Sobre este título" puede pertenecer a otra edición de este libro.
Librería: moluna, Greven, Alemania
Condición: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Vyakaranam BharatBharat Vyakaranam received his B.S. and M.S degrees in the from the Jawaharlal Nehru Technological University and his Ph.D. degree from the Cleveland State University. F. Eugenio Villaseca received his BS from Univer. Nº de ref. del artículo: 5146449
Cantidad disponible: Más de 20 disponibles
Librería: Books Puddle, New York, NY, Estados Unidos de America
Condición: New. pp. 300. Nº de ref. del artículo: 26128810020
Cantidad disponible: 4 disponibles
Librería: Majestic Books, Hounslow, Reino Unido
Condición: New. Print on Demand pp. 300 2:B&W 6 x 9 in or 229 x 152 mm Perfect Bound on Creme w/Gloss Lam. Nº de ref. del artículo: 131777531
Cantidad disponible: 4 disponibles
Librería: preigu, Osnabrück, Alemania
Taschenbuch. Condición: Neu. Dynamic Modeling and Analysis of FACTS controllers | Dynamic harmonic evolution of FACTS | Bharat Vyakaranam (u. a.) | Taschenbuch | Englisch | LAP Lambert Academic Publishing | EAN 9783659295287 | Verantwortliche Person für die EU: preigu GmbH & Co. KG, Lengericher Landstr. 19, 49078 Osnabrück, mail[at]preigu[dot]de | Anbieter: preigu. Nº de ref. del artículo: 106123971
Cantidad disponible: 5 disponibles
Librería: Biblios, Frankfurt am main, HESSE, Alemania
Condición: New. PRINT ON DEMAND pp. 300. Nº de ref. del artículo: 18128810030
Cantidad disponible: 4 disponibles
Librería: AHA-BUCH GmbH, Einbeck, Alemania
Taschenbuch. Condición: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Flexible alternating current transmission system (FACTS) and multi-line FACTS controllers play an important role in electrical power transmission systems by improving power quality and increasing power transmission capacity. These controllers are nonlinear and highly complex. Therefore, during transient conditions, it is very difficult to use conventional time and frequency domain techniques alone to determine the precise dynamic behavior of the harmonics introduced into the system by these controllers. In particular, the time-varying nature of the harmonic components is not captured by these techniques. This book consists of new dynamic models for seven important and popular FACTS controllers using a technique called the dynamic harmonic domain method. These models are more accurate than existing models. The models were simulated in the presence of disturbances to show the evolution in time of the harmonic coefficients and power quality indices. This detailed information about dynamic harmonic response is useful for power quality assessment and can be used as a tool for analyzing the system under the steady state and transient conditions and designing better control circuits. Nº de ref. del artículo: 9783659295287
Cantidad disponible: 2 disponibles
Librería: Mispah books, Redhill, SURRE, Reino Unido
Paperback. Condición: Like New. LIKE NEW. SHIPS FROM MULTIPLE LOCATIONS. book. Nº de ref. del artículo: ERICA79636592952806
Cantidad disponible: 1 disponibles