Poor adaptations of acrylic resin denture bases to the supporting tissues markedly decrease denture retention. Several denture base resin and processing techniques have been introduced to the profession, each claiming to produce a more accurate base. Microwave processing techniques has been introduced claims to minimize the dimensional changes.This purpose of this study was to compare the dimensional accuracy of three denture base resins when processed both by conventional water bath method and by use of microwave energy. Three Poly (MethylMethacrylate) heat cure resins selected for this study. These resins were processed by conventional water bath technique for 1 1/2 hours at 75 degree & half hour at 100 degree and by microwave energy for 3 mins at 500W. The measurements of acrylic resin denture base specimens were compared with the measurements of master metal die dimension keeping it as a standard measurement. The mean values of the difference in the points compared were calculated, & compared to each other to determine if there was a statistically significant difference between them at the 0.05 probability level using the students’ independent test for pooled variances
"Sinopsis" puede pertenecer a otra edición de este libro.
Poor adaptations of acrylic resin denture bases to the supporting tissues markedly decrease denture retention. Several denture base resin and processing techniques have been introduced to the profession, each claiming to produce a more accurate base. Microwave processing techniques has been introduced claims to minimize the dimensional changes.This purpose of this study was to compare the dimensional accuracy of three denture base resins when processed both by conventional water bath method and by use of microwave energy. Three Poly (MethylMethacrylate) heat cure resins selected for this study. These resins were processed by conventional water bath technique for 1 1/2 hours at 75 degree & half hour at 100 degree and by microwave energy for 3 mins at 500W. The measurements of acrylic resin denture base specimens were compared with the measurements of master metal die dimension keeping it as a standard measurement. The mean values of the difference in the points compared were calculated, & compared to each other to determine if there was a statistically significant difference between them at the 0.05 probability level using the students' independent test for pooled variances
Dr.Naveen S Yadav Has done his Post-graduation in 2000 from Rajiv Gandhi University of Health Sciences, Bangalore, India in subject of Prosthodontics. He is Teacher and Examiner for both undergraduates and postgraduates. He has more than 12 years experience in Teaching and Clinical Work.He is the associate editor of Journal of Orofacial Research.
"Sobre este título" puede pertenecer a otra edición de este libro.
Librería: AHA-BUCH GmbH, Einbeck, Alemania
Taschenbuch. Condición: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Poor adaptations of acrylic resin denture bases to the supporting tissues markedly decrease denture retention. Several denture base resin and processing techniques have been introduced to the profession, each claiming to produce a more accurate base. Microwave processing techniques has been introduced claims to minimize the dimensional changes.This purpose of this study was to compare the dimensional accuracy of three denture base resins when processed both by conventional water bath method and by use of microwave energy. Three Poly (MethylMethacrylate) heat cure resins selected for this study. These resins were processed by conventional water bath technique for 1 1/2 hours at 75 degree & half hour at 100 degree and by microwave energy for 3 mins at 500W. The measurements of acrylic resin denture base specimens were compared with the measurements of master metal die dimension keeping it as a standard measurement. The mean values of the difference in the points compared were calculated, & compared to each other to determine if there was a statistically significant difference between them at the 0.05 probability level using the students independent test for pooled variances. Nº de ref. del artículo: 9783659160004
Cantidad disponible: 2 disponibles
Librería: moluna, Greven, Alemania
Condición: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Yadav NaveenDr.Naveen S Yadav Has done his Post-graduation in 2000 from Rajiv Gandhi University of Health Sciences, Bangalore, India in subject of Prosthodontics. He is Teacher and Examiner for both undergraduates and postgraduates. . Nº de ref. del artículo: 5135912
Cantidad disponible: Más de 20 disponibles
Librería: Mispah books, Redhill, SURRE, Reino Unido
Paperback. Condición: Like New. LIKE NEW. SHIPS FROM MULTIPLE LOCATIONS. book. Nº de ref. del artículo: ERICA79636591600086
Cantidad disponible: 1 disponibles