123 phase and hence have no direct bearing on the retention time of solutes. However in gas-solid chromatography, a considerable quantity of the mobile phase may be adsorbed on the surface of the stationary adsorbent which diminishes the column's effective length and ability to retain solutes. In this respect helium has been found to be preferable to most other gases (GREENE and Roy, 1957) because it is adsorbed to the least extent. 3. Packed columns offer a considerable resistance to flow, which may create a pressure differential between inlet and outlet of sufficient magnitude to cause an unfavorable flow rate through a significant length of the column. A reduced inlet/outlet pressure ratio can be obtained by using light molecular weight gases toward which the column packing shows the greatest permeability. The flow rate of the mobile phase is normally adjusted by altering the column inlet pressure, for which purpose commercial pressure regulators of sufficient accuracy are available. Quantitative measurements of the flow rate can be made by a number of methods, including rotameters, orifice meters, soapfilm flow meters and displacement of water. The former two methods are the most con- venient but the least accurate; moreover they create a back pressure and are temperature dependent whereas although the moving soap bubble is cumbersome to employ and unusable for continuous readings, it is preferred when the highest accuracy is required.
"Sinopsis" puede pertenecer a otra edición de este libro.
123 phase and hence have no direct bearing on the retention time of solutes. However in gas-solid chromatography, a considerable quantity of the mobile phase may be adsorbed on the surface of the stationary adsorbent which diminishes the column's effective length and ability to retain solutes. In this respect helium has been found to be preferable to most other gases (GREENE and Roy, 1957) because it is adsorbed to the least extent. 3. Packed columns offer a considerable resistance to flow, which may create a pressure differential between inlet and outlet of sufficient magnitude to cause an unfavorable flow rate through a significant length of the column. A reduced inlet/outlet pressure ratio can be obtained by using light molecular weight gases toward which the column packing shows the greatest permeability. The flow rate of the mobile phase is normally adjusted by altering the column inlet pressure, for which purpose commercial pressure regulators of sufficient accuracy are available. Quantitative measurements of the flow rate can be made by a number of methods, including rotameters, orifice meters, soapfilm flow meters and displacement of water. The former two methods are the most con venient but the least accurate; moreover they create a back pressure and are temperature dependent whereas although the moving soap bubble is cumbersome to employ and unusable for continuous readings, it is preferred when the highest accuracy is required.
"Sobre este título" puede pertenecer a otra edición de este libro.
EUR 29,47 gastos de envío desde Estados Unidos de America a España
Destinos, gastos y plazos de envíoLibrería: Orca Knowledge Systems, Inc., Novato, CA, Estados Unidos de America
Hardcover. Condición: Good. Modern Methods of Plant Analysis: Volume V (Moderne Methoden der PflanzenAnalyse). No DJ. Text in German and English. Usual library markings. Binding is tight, text clean. 535pp. Nº de ref. del artículo: 201218
Cantidad disponible: 1 disponibles
Librería: DieBücheroma123, Prackenbach, Alemania
Gebundene Ausgabe. Condición: Gut. 563 Seiten; Ausgabe von 1962, ausgesondertes Büchereibuch 30665x (P) Sprache: Englisch Gewicht in Gramm: 500. Nº de ref. del artículo: 106951
Cantidad disponible: 1 disponibles