This lack of interest in the composition of intravenous fluids among the medical profession has for decades been causing substantial problems in fluid management resulting from clinicians’ failure to differentiate between the concepts of volume replacement and fluid replacement: “Fluid is poured into the interstitial space on clinical information gained from changes in the intravascular space, such as blood pressures, pulse rate, peripheral temperature, urine output, etc. The end point ... peripheral or pulmonary oedema” [Twigley 1985].
"Sinopsis" puede pertenecer a otra edición de este libro.
Librería: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Alemania
Taschenbuch. Condición: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -This lack of interest in the composition of intravenous fluids among the medical profession has for decades been causing substantial problems in fluid management resulting from clinicians' failure to differentiate between the concepts of volume replacement and fluid replacement: 'Fluid is poured into the interstitial space on clinical information gained from changes in the intravascular space, such as blood pressures, pulse rate, peripheral temperature, urine output, etc. The end point . peripheral or pulmonary oedema' [Twigley 1985]. 124 pp. Englisch. Nº de ref. del artículo: 9783347128514
Cantidad disponible: 2 disponibles
Librería: buchversandmimpf2000, Emtmannsberg, BAYE, Alemania
Taschenbuch. Condición: Neu. This item is printed on demand - Print on Demand Titel. Neuware -This lack of interest in the composition of intravenous fluids among the medical profession has for decades been causing substantial problems in fluid management resulting from clinicians¿ failure to differentiate between the concepts of volume replacement and fluid replacement: ¿Fluid is poured into the interstitial space on clinical information gained from changes in the intravascular space, such as blood pressures, pulse rate, peripheral temperature, urine output, etc. The end point . peripheral or pulmonary oedemä [Twigley 1985].tredition, Heinz-Beusen-Stieg 5, 22926 Ahrensburg 124 pp. Englisch. Nº de ref. del artículo: 9783347128514
Cantidad disponible: 1 disponibles
Librería: preigu, Osnabrück, Alemania
Taschenbuch. Condición: Neu. Fluid Management | Second expanded (corrected) edition | Rolf Zander | Taschenbuch | Englisch | 2020 | tredition | EAN 9783347128514 | Verantwortliche Person für die EU: tredition GmbH, Heinz-Beusen-Stieg 5, 22926 Ahrensburg, support[at]tredition[dot]com | Anbieter: preigu. Nº de ref. del artículo: 119357944
Cantidad disponible: 5 disponibles