Artículos relacionados a Ultra-Low-Voltage Frequency Synthesizer and Successive-Appro...

Ultra-Low-Voltage Frequency Synthesizer and Successive-Approximation Analog-to-Digital Converter for Biomedical Applications (Analog Circuits and Signal Processing) - Tapa dura

 
9783030888442: Ultra-Low-Voltage Frequency Synthesizer and Successive-Approximation Analog-to-Digital Converter for Biomedical Applications (Analog Circuits and Signal Processing)

Sinopsis

This book introduces the origin of biomedical signals and the operating principles behind them and introduces the characteristics of common biomedical signals for subsequent signal measurement and judgment. Since biomedical signals are captured by wearable devices, sensor devices, or implanted devices, these devices are all battery-powered to maintain long working time. We hope to reduce their power consumption to extend service life, especially for implantable devices, because battery replacement can only be done through surgery. Therefore, we must understand how to design low-power integrated circuits.

Both implantable and in-vitro medical signal detectors require two basic components to collect and transmit biomedical signals: an analog-to-digital converter and a frequency synthesizer because these measured biomedical signals are wirelessly transmitted to the relevant receiving unit. The core unit of wireless transmission is the frequency synthesizer, which provides a wide frequency range and stable frequency to demonstrate the quality and performance of the wireless transmitter. Therefore, the basic operating principle and model of the frequency synthesizer are introduced. We also show design examples and measurement results of a low-power low-voltage integer-N frequency synthesizer for biomedical applications. The detection of biomedical signals needs to be converted into digital signals by an analog-to-digital converter to facilitate subsequent signal processing and recognition. Therefore, the operating principle of the analog-to-digital converter is introduced. We also show implementation examples and measurement results of low-power low-voltage analog-to-digital converters for biomedical applications.

"Sinopsis" puede pertenecer a otra edición de este libro.

Acerca del autor

Chung-Chih Hung received the B.S. degree in electrical engineering from National Taiwan University, Taipei, Taiwan, in 1989, and the M.S. and Ph.D. degrees in electrical engineering from The Ohio State University, Columbus, Ohio in 1993 and 1997, respectively. From 1997 to 2003, he worked for several IC design companies in San Jose, CA and San Diego, CA, where he held analog circuit design manager and director positions and successfully designed many chips in mass production. Since 2003, he has been with National Yang Ming Chiao Tung University, Hsinchu, Taiwan, where he is currently a Professor in the Department of Electrical and Computer Engineering. He is the Deputy Director of the Biomedical Electronics Translational Research Center (BETRC) in National Yang Ming Chiao Tung University. Dr. Hung has served on the Steering Committees of the IEEE MWSCAS and technical program committees of some IEEE conferences. He and his students have won several Best Paper Awards at international conferences. He has been the Deputy Editor-In-Chief of Analog Integrated Circuits and Signal Processing since 2013 and currently serve as Associate Editor of IEEE Transactions on Biomedical Circuits and Systems. Dr. Hung has authored/co-authored over 100 peer-reviewed papers and book chapters and held several US patents. His research interests include the design of analog and mixed-signal integrated circuits for biomedical, power management, and communication applications.

 

 

Shih-Hsing Wang received the M.S. degree in Electronics Engineering from National Taiwan University of Science and Technology, Taipei, Taiwan, in 1993 and Ph.D. degree in electrical and computer engineering from National Chiao Tung University, Hsinchu, Taiwan in 2020.  From 1993 to now, he has been working in several IC design companies in Hsinchu Science Park, Taiwan. He is currently the head of Memory Design and Analysis Division in Etron Technology, Inc. Hehas published 17 US patents in the DRAM/ADC/PLL related fields. His research interests include high-speed DRAM circuit, mixed-signal ADC/DAC circuit, and PLL/DLL circuit design.

De la contraportada

This book introduces the origin of biomedical signals and the operating principles behind them and presents the characteristics of common biomedical signals for subsequent signal measurement and judgment. Since biomedical signals are captured by wearable devices, sensor devices, or implanted devices, these devices are all battery-powered to maintain long working time. We hope to reduce their power consumption to extend service life, especially for implantable devices, because battery replacement can only be done through surgery. Therefore, we must understand how to design low-voltage low-power integrated circuits. 

  • Provides necessary background information on biomedical signals and proceeds with design considerations for low supply voltage analog circuits;
  • Describes design techniques for not only frequency synthesizers and ADCs, but also the ultra-low voltage design techniques of these circuits;
  • Demonstrates examples to overcome typical design challenges.

 


"Sobre este título" puede pertenecer a otra edición de este libro.

Comprar usado

Condición: Como Nuevo
Unread book in perfect condition...
Ver este artículo

EUR 17,14 gastos de envío desde Estados Unidos de America a España

Destinos, gastos y plazos de envío

Comprar nuevo

Ver este artículo

EUR 5,17 gastos de envío desde Reino Unido a España

Destinos, gastos y plazos de envío

Otras ediciones populares con el mismo título

9783030888473: Ultra-Low-Voltage Frequency Synthesizer and Successive-Approximation Analog-to-Digital Converter for Biomedical Applications (Analog Circuits and Signal Processing)

Edición Destacada

ISBN 10:  3030888479 ISBN 13:  9783030888473
Editorial: Springer, 2022
Tapa blanda

Resultados de la búsqueda para Ultra-Low-Voltage Frequency Synthesizer and Successive-Appro...

Imagen de archivo

Hung, Chung-Chih; Wang, Shih-Hsing
Publicado por Springer, 2021
ISBN 10: 3030888444 ISBN 13: 9783030888442
Nuevo Tapa dura

Librería: Ria Christie Collections, Uxbridge, Reino Unido

Calificación del vendedor: 5 de 5 estrellas Valoración 5 estrellas, Más información sobre las valoraciones de los vendedores

Condición: New. In. Nº de ref. del artículo: ria9783030888442_new

Contactar al vendedor

Comprar nuevo

EUR 91,07
Convertir moneda
Gastos de envío: EUR 5,17
De Reino Unido a España
Destinos, gastos y plazos de envío

Cantidad disponible: Más de 20 disponibles

Añadir al carrito

Imagen del vendedor

Hung, Chung-Chih|Wang, Shih-Hsing
ISBN 10: 3030888444 ISBN 13: 9783030888442
Nuevo Tapa dura
Impresión bajo demanda

Librería: moluna, Greven, Alemania

Calificación del vendedor: 5 de 5 estrellas Valoración 5 estrellas, Más información sobre las valoraciones de los vendedores

Gebunden. Condición: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. This book introduces the origin of biomedical signals and the operating principles behind them and introduces the characteristics of common biomedical signals for subsequent signal measurement and judgment.This book introduces the origin of biomedica. Nº de ref. del artículo: 506747952

Contactar al vendedor

Comprar nuevo

EUR 79,10
Convertir moneda
Gastos de envío: EUR 19,49
De Alemania a España
Destinos, gastos y plazos de envío

Cantidad disponible: Más de 20 disponibles

Añadir al carrito

Imagen del vendedor

Shih-Hsing Wang
ISBN 10: 3030888444 ISBN 13: 9783030888442
Nuevo Tapa dura
Impresión bajo demanda

Librería: BuchWeltWeit Ludwig Meier e.K., Bergisch Gladbach, Alemania

Calificación del vendedor: 5 de 5 estrellas Valoración 5 estrellas, Más información sobre las valoraciones de los vendedores

Buch. Condición: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -This book introduces the origin of biomedical signals and the operating principles behind them and introduces the characteristics of common biomedical signals for subsequent signal measurement and judgment. Since biomedical signals are captured by wearable devices, sensor devices, or implanted devices, these devices are all battery-powered to maintain long working time. We hope to reduce their power consumption to extend service life, especially for implantable devices, because battery replacement can only be done through surgery. Therefore, we must understand how to design low-power integrated circuits.Both implantable and in-vitro medical signal detectors require two basic components to collect and transmit biomedical signals: an analog-to-digital converter and a frequency synthesizer because these measured biomedical signals are wirelessly transmitted to the relevant receiving unit. The core unit of wireless transmission is the frequency synthesizer, which provides a wide frequency range and stable frequency to demonstrate the quality and performance of the wireless transmitter. Therefore, the basic operating principle and model of the frequency synthesizer are introduced. We also show design examples and measurement results of a low-power low-voltage integer-N frequency synthesizer for biomedical applications. The detection of biomedical signals needs to be converted into digital signals by an analog-to-digital converter to facilitate subsequent signal processing and recognition. Therefore, the operating principle of the analog-to-digital converter is introduced. We also show implementation examples and measurement results of low-power low-voltage analog-to-digital converters for biomedical applications. 232 pp. Englisch. Nº de ref. del artículo: 9783030888442

Contactar al vendedor

Comprar nuevo

EUR 90,94
Convertir moneda
Gastos de envío: EUR 11,00
De Alemania a España
Destinos, gastos y plazos de envío

Cantidad disponible: 2 disponibles

Añadir al carrito

Imagen del vendedor

Shih-Hsing Wang
Publicado por Springer International Publishing, 2021
ISBN 10: 3030888444 ISBN 13: 9783030888442
Nuevo Tapa dura

Librería: AHA-BUCH GmbH, Einbeck, Alemania

Calificación del vendedor: 5 de 5 estrellas Valoración 5 estrellas, Más información sobre las valoraciones de los vendedores

Buch. Condición: Neu. Druck auf Anfrage Neuware - Printed after ordering - This book introduces the origin of biomedical signals and the operating principles behind them and introduces the characteristics of common biomedical signals for subsequent signal measurement and judgment. Since biomedical signals are captured by wearable devices, sensor devices, or implanted devices, these devices are all battery-powered to maintain long working time. We hope to reduce their power consumption to extend service life, especially for implantable devices, because battery replacement can only be done through surgery. Therefore, we must understand how to design low-power integrated circuits.Both implantable and in-vitro medical signal detectors require two basic components to collect and transmit biomedical signals: an analog-to-digital converter and a frequency synthesizer because these measured biomedical signals are wirelessly transmitted to the relevant receiving unit. The core unit of wireless transmission is the frequency synthesizer, which provides a wide frequency range and stable frequency to demonstrate the quality and performance of the wireless transmitter. Therefore, the basic operating principle and model of the frequency synthesizer are introduced. We also show design examples and measurement results of a low-power low-voltage integer-N frequency synthesizer for biomedical applications. The detection of biomedical signals needs to be converted into digital signals by an analog-to-digital converter to facilitate subsequent signal processing and recognition. Therefore, the operating principle of the analog-to-digital converter is introduced. We also show implementation examples and measurement results of low-power low-voltage analog-to-digital converters for biomedical applications. Nº de ref. del artículo: 9783030888442

Contactar al vendedor

Comprar nuevo

EUR 90,94
Convertir moneda
Gastos de envío: EUR 11,99
De Alemania a España
Destinos, gastos y plazos de envío

Cantidad disponible: 1 disponibles

Añadir al carrito

Imagen de archivo

Hung, Chung-chih; Wang, Shih-hsing
Publicado por Springer, 2021
ISBN 10: 3030888444 ISBN 13: 9783030888442
Nuevo Tapa dura

Librería: GreatBookPricesUK, Woodford Green, Reino Unido

Calificación del vendedor: 5 de 5 estrellas Valoración 5 estrellas, Más información sobre las valoraciones de los vendedores

Condición: New. Nº de ref. del artículo: 44121607-n

Contactar al vendedor

Comprar nuevo

EUR 91,06
Convertir moneda
Gastos de envío: EUR 17,27
De Reino Unido a España
Destinos, gastos y plazos de envío

Cantidad disponible: Más de 20 disponibles

Añadir al carrito

Imagen del vendedor

Hung, Chung-chih; Wang, Shih-hsing
Publicado por Springer, 2021
ISBN 10: 3030888444 ISBN 13: 9783030888442
Nuevo Tapa dura

Librería: GreatBookPrices, Columbia, MD, Estados Unidos de America

Calificación del vendedor: 5 de 5 estrellas Valoración 5 estrellas, Más información sobre las valoraciones de los vendedores

Condición: New. Nº de ref. del artículo: 44121607-n

Contactar al vendedor

Comprar nuevo

EUR 94,85
Convertir moneda
Gastos de envío: EUR 17,14
De Estados Unidos de America a España
Destinos, gastos y plazos de envío

Cantidad disponible: Más de 20 disponibles

Añadir al carrito

Imagen de archivo

Hung, Chung-Chih; Wang, Shih-Hsing
Publicado por Springer, 2021
ISBN 10: 3030888444 ISBN 13: 9783030888442
Nuevo Tapa dura

Librería: California Books, Miami, FL, Estados Unidos de America

Calificación del vendedor: 5 de 5 estrellas Valoración 5 estrellas, Más información sobre las valoraciones de los vendedores

Condición: New. Nº de ref. del artículo: I-9783030888442

Contactar al vendedor

Comprar nuevo

EUR 105,95
Convertir moneda
Gastos de envío: EUR 6,86
De Estados Unidos de America a España
Destinos, gastos y plazos de envío

Cantidad disponible: Más de 20 disponibles

Añadir al carrito

Imagen del vendedor

Hung, Chung-chih; Wang, Shih-hsing
Publicado por Springer, 2021
ISBN 10: 3030888444 ISBN 13: 9783030888442
Antiguo o usado Tapa dura

Librería: GreatBookPrices, Columbia, MD, Estados Unidos de America

Calificación del vendedor: 5 de 5 estrellas Valoración 5 estrellas, Más información sobre las valoraciones de los vendedores

Condición: As New. Unread book in perfect condition. Nº de ref. del artículo: 44121607

Contactar al vendedor

Comprar usado

EUR 100,10
Convertir moneda
Gastos de envío: EUR 17,14
De Estados Unidos de America a España
Destinos, gastos y plazos de envío

Cantidad disponible: Más de 20 disponibles

Añadir al carrito

Imagen del vendedor

Hung, Chung-chih; Wang, Shih-hsing
Publicado por Springer, 2021
ISBN 10: 3030888444 ISBN 13: 9783030888442
Antiguo o usado Tapa dura

Librería: GreatBookPricesUK, Woodford Green, Reino Unido

Calificación del vendedor: 5 de 5 estrellas Valoración 5 estrellas, Más información sobre las valoraciones de los vendedores

Condición: As New. Unread book in perfect condition. Nº de ref. del artículo: 44121607

Contactar al vendedor

Comprar usado

EUR 101,38
Convertir moneda
Gastos de envío: EUR 17,27
De Reino Unido a España
Destinos, gastos y plazos de envío

Cantidad disponible: Más de 20 disponibles

Añadir al carrito

Imagen del vendedor

Shih-Hsing Wang
ISBN 10: 3030888444 ISBN 13: 9783030888442
Nuevo Tapa dura

Librería: buchversandmimpf2000, Emtmannsberg, BAYE, Alemania

Calificación del vendedor: 5 de 5 estrellas Valoración 5 estrellas, Más información sobre las valoraciones de los vendedores

Buch. Condición: Neu. Neuware -This book introduces the origin of biomedical signals and the operating principles behind them and introduces the characteristics of common biomedical signals for subsequent signal measurement and judgment. Since biomedical signals are captured by wearable devices, sensor devices, or implanted devices, these devices are all battery-powered to maintain long working time. We hope to reduce their power consumption to extend service life, especially for implantable devices, because battery replacement can only be done through surgery. Therefore, we must understand how to design low-power integrated circuits.Both implantable and in-vitro medical signal detectors require two basic components to collect and transmit biomedical signals: an analog-to-digital converter and a frequency synthesizer because these measured biomedical signals are wirelessly transmitted to the relevant receiving unit. The core unit of wireless transmission is the frequency synthesizer, which provides a wide frequency range and stable frequency to demonstrate the quality and performance of the wireless transmitter. Therefore, the basic operating principle and model of the frequency synthesizer are introduced. We also show design examples and measurement results of a low-power low-voltage integer-N frequency synthesizer for biomedical applications. The detection of biomedical signals needs to be converted into digital signals by an analog-to-digital converter to facilitate subsequent signal processing and recognition. Therefore, the operating principle of the analog-to-digital converter is introduced. We also show implementation examples and measurement results of low-power low-voltage analog-to-digital converters for biomedical applications.Springer Verlag GmbH, Tiergartenstr. 17, 69121 Heidelberg 232 pp. Englisch. Nº de ref. del artículo: 9783030888442

Contactar al vendedor

Comprar nuevo

EUR 90,94
Convertir moneda
Gastos de envío: EUR 35,00
De Alemania a España
Destinos, gastos y plazos de envío

Cantidad disponible: 2 disponibles

Añadir al carrito

Existen otras 1 copia(s) de este libro

Ver todos los resultados de su búsqueda