Excerpt from Investigation of Extended Bulb Angle Sections Under Compression: Part One, as Euler Columns; Part Two, as Stiffeners Attached to Sheet; Thesis
This investigation has established the following facts Above an effective length/radius of gyration of about 78, extruded bulb angle sections follow the Euler curve. In the short column range the Straight Line Formula gives a more conservative value than the Johnson Parabolic Formula. From the experimental data the proportional limit for 24st extruded sections was found to be 17006 lhs/ing. When investigating extruded bulb angle sections used as columns for possible local plate failure, since the condition of support at the base of the angle is neither clamped nor simply supported, but an intermediate case, it is suggested that a value of K equal to be used in the formula of Timoshenko for plate failure, when the ratio length/width is greater than four. Unfor tunately, this suggestion is made on the basis of only.
About the Publisher
Forgotten Books publishes hundreds of thousands of rare and classic books. Find more at www.forgottenbooks.com
This book is a reproduction of an important historical work. Forgotten Books uses state-of-the-art technology to digitally reconstruct the work, preserving the original format whilst repairing imperfections present in the aged copy. In rare cases, an imperfection in the original, such as a blemish or missing page, may be replicated in our edition. We do, however, repair the vast majority of imperfections successfully; any imperfections that remain are intentionally left to preserve the state of such historical works.
"Sinopsis" puede pertenecer a otra edición de este libro.
Librería: Forgotten Books, London, Reino Unido
Paperback. Condición: New. Print on Demand. This book investigates the behavior of extruded bulb angle sections when used as columns for possible local plate failure and when acting as stiffeners attached to sheet, as seen in aeronautical construction. The author established that above an effective length/radius of gyration of about 78, extruded bulb angle sections follow the Euler curve. In the short column range, the Straight Line Formula gives a more conservative value than the Johnson Parabolic Formula. From the experimental data, the proportional limit for 24ST extruded sections was found to be 17006 lbs/in2. When investigating extruded bulb angle sections used as columns for possible local plate failure, the author suggests that a value of K equal to 3 be used in the formula of Timoshenko for plate failure, when the ratio length/width is greater than four. The author offers these insights on the basis of experimental plate failures. This book is a reproduction of an important historical work, digitally reconstructed using state-of-the-art technology to preserve the original format. In rare cases, an imperfection in the original, such as a blemish or missing page, may be replicated in the book. print-on-demand item. Nº de ref. del artículo: 9781528126359_0
Cantidad disponible: Más de 20 disponibles
Librería: PBShop.store US, Wood Dale, IL, Estados Unidos de America
PAP. Condición: New. New Book. Shipped from UK. Established seller since 2000. Nº de ref. del artículo: LX-9781528126359
Cantidad disponible: 15 disponibles
Librería: PBShop.store UK, Fairford, GLOS, Reino Unido
PAP. Condición: New. New Book. Shipped from UK. Established seller since 2000. Nº de ref. del artículo: LX-9781528126359
Cantidad disponible: 15 disponibles