This report describes the results of calculations using the NIST Fire Dynamics Simulator (FDS) performed to provide insight on the thermal conditions that may have occurred during a wind-driven fire in a one-story ranch house on April 12, 2009 in Houston, Texas. The FDS simulations represented the building geometry, material thermal properties, and fire behavior based on information gathered from multiple sources. The simulation results are provided in this report. The FDS simulation that best represents the witnessed fire conditions indicate that fire spread throughout the attic and first floor developed a wind-driven flow with temperatures in excess of 260 °C (500 °F) between the den and front door. The critical event in this fire was the creation of a wind-driven flow path between a large span of failed windows on the upwind side of the structure, and the open front door on the downwind side of the structure. Floor-to-ceiling temperatures rapidly increased in the flow path, in which members were performing interior operations. In a simulation without wind, the flow path was not created after the large span of windows failed, and the thermal environment surrounding the location of interior operations improved.
"Sinopsis" puede pertenecer a otra edición de este libro.
This report describes the results of calculations using the NIST Fire Dynamics Simulator (FDS) performed to provide insight on the thermal conditions that may have occurred during a wind-driven fire in a one-story ranch house on April 12, 2009 in Houston, Texas. The FDS simulations represented the building geometry, material thermal properties, and fire behavior based on information gathered from multiple sources. The simulation results are provided in this report. The FDS simulation that best represents the witnessed fire conditions indicate that fire spread throughout the attic and first floor developed a wind-driven flow with temperatures in excess of 260 °C (500 °F) between the den and front door. The critical event in this fire was the creation of a wind-driven flow path between a large span of failed windows on the upwind side of the structure, and the open front door on the downwind side of the structure. Floor-to-ceiling temperatures rapidly increased in the flow path, in which members were performing interior operations. In a simulation without wind, the flow path was not created after the large span of windows failed, and the thermal environment surrounding the location of interior operations improved.
"Sobre este título" puede pertenecer a otra edición de este libro.
Librería: GreatBookPrices, Columbia, MD, Estados Unidos de America
Condición: As New. Unread book in perfect condition. Nº de ref. del artículo: 21157391
Cantidad disponible: Más de 20 disponibles
Librería: THE SAINT BOOKSTORE, Southport, Reino Unido
Paperback / softback. Condición: New. This item is printed on demand. New copy - Usually dispatched within 5-9 working days. Nº de ref. del artículo: C9781496136602
Cantidad disponible: Más de 20 disponibles
Librería: GreatBookPrices, Columbia, MD, Estados Unidos de America
Condición: New. Nº de ref. del artículo: 21157391-n
Cantidad disponible: Más de 20 disponibles
Librería: GreatBookPricesUK, Woodford Green, Reino Unido
Condición: As New. Unread book in perfect condition. Nº de ref. del artículo: 21157391
Cantidad disponible: Más de 20 disponibles
Librería: GreatBookPricesUK, Woodford Green, Reino Unido
Condición: New. Nº de ref. del artículo: 21157391-n
Cantidad disponible: Más de 20 disponibles
Librería: CitiRetail, Stevenage, Reino Unido
Paperback. Condición: new. Paperback. This report describes the results of calculations using the NIST Fire Dynamics Simulator (FDS) performed to provide insight on the thermal conditions that may have occurred during a wind-driven fire in a one-story ranch house on April 12, 2009 in Houston, Texas. The FDS simulations represented the building geometry, material thermal properties, and fire behavior based on information gathered from multiple sources. The simulation results are provided in this report. The FDS simulation that best represents the witnessed fire conditions indicate that fire spread throughout the attic and first floor developed a wind-driven flow with temperatures in excess of 260 0C (500 0F) between the den and front door. The critical event in this fire was the creation of a wind-driven flow path between a large span of failed windows on the upwind side of the structure, and the open front door on the downwind side of the structure. Floor-to-ceiling temperatures rapidly increased in the flow path, in which members were performing interior operations. In a simulation without wind, the flow path was not created after the large span of windows failed, and the thermal environment surrounding the location of interior operations improved. This item is printed on demand. Shipping may be from our UK warehouse or from our Australian or US warehouses, depending on stock availability. Nº de ref. del artículo: 9781496136602
Cantidad disponible: 1 disponibles