A performance comparison of 14 rescue breathing apparatus was undertaken as an assessment of past and present worldwide technology. Rescue breathing apparatus are self-contained, close-circuit breathing apparatus used for entry into areas having atmospheres that are immediately dangerous to life and health. Apparatus tested were the Biomarine BioPak 45, 60, and 240; the Draeger BG4 and BG-174A; the Litton LITPAC II; the MSA Custo, 4500 II Air Mask, Chemox, and McCaa; the Sabre Selected Elevated Flow Apparatus (SEFA); the Scott Rescue-Pak; the Siebe Gorman Aerorlox and Proto Ten; and the Survivair LP-120. Physiological parameters monitored during the testing were average inhaled CO2 and O2, minimum inhaled CO2, inhaled wet-and dry-bulb temperatures, and peak inhalation and exhalation breathing pressures. The metabolic demand on the apparatus was 1.35 L O2/min, the first beginning 10 min into the test and the second beginning 10 min before the end of the rated duration of the apparatus. Results presented include apparatus service life and test-averages of monitored physiological parameters. Schematic drawings and photographs of the apparatus are also included.
"Sinopsis" puede pertenecer a otra edición de este libro.
A performance comparison of 14 rescue breathing apparatus was undertaken as an assessment of past and present worldwide technology. Rescue breathing apparatus are self-contained, close-circuit breathing apparatus used for entry into areas having atmospheres that are immediately dangerous to life and health. Apparatus tested were the Biomarine BioPak 45, 60, and 240; the Draeger BG4 and BG-174A; the Litton LITPAC II; the MSA Custo, 4500 II Air Mask, Chemox, and McCaa; the Sabre Selected Elevated Flow Apparatus (SEFA); the Scott Rescue-Pak; the Siebe Gorman Aerorlox and Proto Ten; and the Survivair LP-120. Physiological parameters monitored during the testing were average inhaled CO2 and O2, minimum inhaled CO2, inhaled wet-and dry-bulb temperatures, and peak inhalation and exhalation breathing pressures. The metabolic demand on the apparatus was 1.35 L O2/min, the first beginning 10 min into the test and the second beginning 10 min before the end of the rated duration of the apparatus. Results presented include apparatus service life and test-averages of monitored physiological parameters. Schematic drawings and photographs of the apparatus are also included.
"Sobre este título" puede pertenecer a otra edición de este libro.
Librería: Majestic Books, Hounslow, Reino Unido
Condición: New. Print on Demand pp. 38. Nº de ref. del artículo: 393564310
Cantidad disponible: 4 disponibles
Librería: Books Puddle, Woodside, NY, Estados Unidos de America
Condición: New. Print on Demand pp. 38. Nº de ref. del artículo: 26386068297
Cantidad disponible: 4 disponibles
Librería: Biblios, Frankfurt am main, HESSE, Alemania
Condición: New. PRINT ON DEMAND pp. 38. Nº de ref. del artículo: 18386068291
Cantidad disponible: 4 disponibles
Librería: THE SAINT BOOKSTORE, Southport, Reino Unido
Paperback / softback. Condición: New. This item is printed on demand. New copy - Usually dispatched within 5-9 working days. Nº de ref. del artículo: C9781288539123
Cantidad disponible: Más de 20 disponibles
Librería: AHA-BUCH GmbH, Einbeck, Alemania
Taschenbuch. Condición: Neu. Neuware - A performance comparison of 14 rescue breathing apparatus was undertaken as an assessment of past and present worldwide technology. Rescue breathing apparatus are self-contained, close-circuit breathing apparatus used for entry into areas having atmospheres that are immediately dangerous to life and health. Apparatus tested were the Biomarine BioPak 45, 60, and 240; the Draeger BG4 and BG-174A; the Litton LITPAC II; the MSA Custo, 4500 II Air Mask, Chemox, and McCaa; the Sabre Selected Elevated Flow Apparatus (SEFA); the Scott Rescue-Pak; the Siebe Gorman Aerorlox and Proto Ten; and the Survivair LP-120. Physiological parameters monitored during the testing were average inhaled CO2 and O2, minimum inhaled CO2, inhaled wet-and dry-bulb temperatures, and peak inhalation and exhalation breathing pressures. The metabolic demand on the apparatus was 1.35 L O2/min, the first beginning 10 min into the test and the second beginning 10 min before the end of the rated duration of the apparatus. Results presented include apparatus service life and test-averages of monitored physiological parameters. Schematic drawings and photographs of the apparatus are also included. Nº de ref. del artículo: 9781288539123
Cantidad disponible: 2 disponibles
Librería: moluna, Greven, Alemania
Condición: New. A performance comparison of 14 rescue breathing apparatus was undertaken as an assessment of past and present worldwide technology. Rescue breathing apparatus are self-contained, close-circuit breathing apparatus used for entry into areas having atmospheres. Nº de ref. del artículo: 6571169
Cantidad disponible: Más de 20 disponibles