This revision of the ASCE Standard Practice for Direct Design of Buried Precast Concrete Pipe Using Standard Installations (SIDD) is a replacement of ANSI/ASCE 15-93. This Standard focuses on the direct design of buried precast concrete pipe using Standard Installations, and reviews the design and construction of the soil/pipe interaction system that is used for the conveyance of sewage, industrial wastes, storm water, and drainage. To account for the interaction between pipe and soil envelope when determining loads, pressure distributions, moment, thrust and shear, this volume presents the SIDD method for buried precast concrete pipe. Excavation, safety, foundation, bedding, sheathing removal and trench shield advancement are among those construction requirements for precast concrete pipe designed by the SIDD method that are presented here. This standard practice may be used as a reference in preparing project specifications based on the SIDD method. Four types of standard embankment installations and four types of standard trench installations are covered in the standard. The limits state design procedure specified for the design of pipe is consistent with the procedures outlined in the AASHTO Standard Specifications for Highway Bridges. The commentary provides supporting background data.
"Sinopsis" puede pertenecer a otra edición de este libro.
This revision of the ASCE Standard Practice for Direct Design of Buried Precast Concrete Pipe Using Standard Installations (SIDD) is a replacement of ANSI/ASCE 15-93. This Standard focuses on the direct design of buried precast concrete pipe using Standard Installations, and reviews the design and construction of the soil/pipe interaction system that is used for the conveyance of sewage, industrial wastes, storm water, and drainage. To account for the interaction between pipe and soil envelope when determining loads, pressure distributions, moment, thrust and shear, this volume presents the SIDD method for buried precast concrete pipe. Excavation, safety, foundation, bedding, sheathing removal and trench shield advancement are among those construction requirements for precast concrete pipe designed by the SIDD method that are presented here. This standard practice may be used as a reference in preparing project specifications based on the SIDD method. Four types of standard embankment installations and four types of standard trench installations are covered in the standard. The limits state design procedure specified for the design of pipe is consistent with the procedures outlined in the AASHTO Standard Specifications for Highway Bridges. The commentary provides supporting background data.
"Sobre este título" puede pertenecer a otra edición de este libro.
Sus derechos de garantía legal: Todos los consumidores de la UE se benefician de al menos dos años de protección de garantía legal para cualquier bien de consumo que se venda en la UE. Ver más
Librería: PBShop.store UK, Fairford, GLOS, Reino Unido
PAP. Condición: New. New Book. Shipped from UK. Established seller since 2000. Nº de ref. del artículo: FW-9780784404713
Cantidad disponible: 1 disponibles
Librería: GreatBookPrices, Columbia, MD, Estados Unidos de America
Condición: New. Nº de ref. del artículo: 15575088-n
Cantidad disponible: 1 disponibles
Librería: Kennys Bookshop and Art Galleries Ltd., Galway, GY, Irlanda
Condición: New. Focuses on the direct design of buried precast concrete pipe using Standard Installations, and reviews the design and construction of the soil/pipe interaction system that is used for the conveyance of sewage, industrial wastes, storm water, and drainage. This volume presents the SIDD method for buried precast concrete pipe. Series: ASCE Standard S. Num Pages: 40 pages, Ill. BIC Classification: TGB; TN. Category: (P) Professional & Vocational; (UP) Postgraduate, Research & Scholarly; (XV) Technical / Manuals. Dimension: 230. . . 2001. Paperback. . . . . Nº de ref. del artículo: V9780784404713
Cantidad disponible: 1 disponibles
Librería: GreatBookPrices, Columbia, MD, Estados Unidos de America
Condición: As New. Unread book in perfect condition. Nº de ref. del artículo: 15575088
Cantidad disponible: 1 disponibles
Librería: THE SAINT BOOKSTORE, Southport, Reino Unido
Paperback / softback. Condición: New. New copy - Usually dispatched within 4 working days. Nº de ref. del artículo: B9780784404713
Cantidad disponible: 1 disponibles
Librería: GreatBookPricesUK, Woodford Green, Reino Unido
Condición: New. Nº de ref. del artículo: 15575088-n
Cantidad disponible: 1 disponibles
Librería: Kennys Bookstore, Olney, MD, Estados Unidos de America
Condición: New. Focuses on the direct design of buried precast concrete pipe using Standard Installations, and reviews the design and construction of the soil/pipe interaction system that is used for the conveyance of sewage, industrial wastes, storm water, and drainage. This volume presents the SIDD method for buried precast concrete pipe. Series: ASCE Standard S. Num Pages: 40 pages, Ill. BIC Classification: TGB; TN. Category: (P) Professional & Vocational; (UP) Postgraduate, Research & Scholarly; (XV) Technical / Manuals. Dimension: 230. . . 2001. Paperback. . . . . Books ship from the US and Ireland. Nº de ref. del artículo: V9780784404713
Cantidad disponible: 1 disponibles
Librería: GreatBookPricesUK, Woodford Green, Reino Unido
Condición: As New. Unread book in perfect condition. Nº de ref. del artículo: 15575088
Cantidad disponible: 1 disponibles
Librería: Revaluation Books, Exeter, Reino Unido
Paperback. Condición: Brand New. 40 pages. 10.75x8.25x0.25 inches. In Stock. Nº de ref. del artículo: __0784404712
Cantidad disponible: 1 disponibles
Librería: moluna, Greven, Alemania
Condición: New. Focuses on the direct design of buried precast concrete pipe using Standard Installations, and reviews the design and construction of the soil/pipe interaction system that is used for the conveyance of sewage, industrial wastes, storm water, and drainage. T. Nº de ref. del artículo: 594986528
Cantidad disponible: 1 disponibles