Masonry walls are not isotropic; they have less strength in bending in the vertical direction than in the horizontal. The design of two-way spanning masonry panels under lateral loads is therefore complicated and tedious.
The design tables in this book present a straightforward and practical approach to the design of rectangular lateral loaded panels under uniformly distributed loads. The tables give the ultimate load capacity of masonry panels of different sizes, properties and edge conditions. They cover both unreinforced and bed joint reinforced masonry panels. The basis of the preparation of the design tables is that presented in BS 5628 Part 1: 1992 and Part 2: 1995.
The load tables will improve the efficiency of the design process and be a considerable asset to the practising engineer.
"Sinopsis" puede pertenecer a otra edición de este libro.
Masonry walls are not isotropic; they have less strength in bending in the vertical direction than in the horizontal. The design of two-way spanning masonry panels under lateral loads is therefore complicated and tedious. The design tables in this book present a straightforward and practical approach to the design of rectangular lateral loaded panels under uniformly distributed loads. The tables give the ultimate load capacity of masonry panels of different sizes, properties and edge conditions. They cover both unreinforced and bed joint reinforced masonry panels.
"Sobre este título" puede pertenecer a otra edición de este libro.
Librería: Books Puddle, New York, NY, Estados Unidos de America
Condición: New. pp. 56. Nº de ref. del artículo: 26457315
Cantidad disponible: 1 disponibles
Librería: Majestic Books, Hounslow, Reino Unido
Condición: New. pp. 56. Nº de ref. del artículo: 7423420
Cantidad disponible: 1 disponibles
Librería: Biblios, Frankfurt am main, HESSE, Alemania
Condición: New. pp. 56. Nº de ref. del artículo: 18457321
Cantidad disponible: 1 disponibles
Librería: PBShop.store UK, Fairford, GLOS, Reino Unido
PAP. Condición: New. New Book. Shipped from UK. Established seller since 2000. Nº de ref. del artículo: FW-9780727725264
Cantidad disponible: 1 disponibles
Librería: GreatBookPrices, Columbia, MD, Estados Unidos de America
Condición: New. Nº de ref. del artículo: 38646716-n
Cantidad disponible: 1 disponibles
Librería: THE SAINT BOOKSTORE, Southport, Reino Unido
Paperback / softback. Condición: New. New copy - Usually dispatched within 4 working days. 218. Nº de ref. del artículo: B9780727725264
Cantidad disponible: 1 disponibles
Librería: Rarewaves USA, OSWEGO, IL, Estados Unidos de America
Paperback. Condición: New. Masonry walls are not isotropic; they have less strength in bending in the vertical direction than in the horizontal. The design of two-way spanning masonry panels under lateral loads is therefore complicated and tedious.The design tables in this book present a straightforward and practical approach to the design of rectangular lateral loaded panels under uniformly distributed loads. The tables give the ultimate load capacity of masonry panels of different sizes, properties and edge conditions. They cover both unreinforced and bed joint reinforced masonry panels. The basis of the preparation of the design tables is that presented in BS 5628 Part 1: 1992 and Part 2: 1995.The load tables will improve the efficiency of the design process and be a considerable asset to the practising engineer. Nº de ref. del artículo: LU-9780727725264
Cantidad disponible: 1 disponibles
Librería: Revaluation Books, Exeter, Reino Unido
Paperback. Condición: Brand New. 1996 edition. 56 pages. 11.42x7.95x0.31 inches. In Stock. Nº de ref. del artículo: __0727725262
Cantidad disponible: 1 disponibles
Librería: GreatBookPricesUK, Woodford Green, Reino Unido
Condición: New. Nº de ref. del artículo: 38646716-n
Cantidad disponible: 1 disponibles
Librería: Kennys Bookshop and Art Galleries Ltd., Galway, GY, Irlanda
Condición: New. Nº de ref. del artículo: V9780727725264
Cantidad disponible: 1 disponibles