Artículos relacionados a Design Tables to Bs8007: Design of Concrete Structures...

Design Tables to Bs8007: Design of Concrete Structures for Retaining Aqueous Liquids - Tapa blanda

 
9780727725172: Design Tables to Bs8007: Design of Concrete Structures for Retaining Aqueous Liquids

Sinopsis

Concrete expands and then contracts because of the increase in temperature during hydration of cement and subsequent fall in temperature. In continuous structures, if this movement is restrained, tensile stresses will develop which can cause cracks to form. Although it is accepted that there will be cracks in reinforced concrete structures, the degree and magnitude of cracking should be controlled. In the design of liquid retaining structures, it is essential to restrict the width of cracks in structures. The maximum design surface crack widths (w) in BS8007 for direct tension and flexure or restrained temperature and moisture effects are as follows: w = 0.2 mm for severe or very severe exposure; and, w = 0.1 mm for critical aesthetic appearance.The design calculations of both the serviceability limit state of cracking due to thermal and moisture effects and flexural can be tedious and time consuming. In the preliminary design stage, the design tables in this document will assist and 'short-cut' the design process and therefore save valuable time. "Design tables to BS8007" has been divided into two parts. Part 1 provides calculations of minimum reinforcement, crack spacing, and crack widths in relation to temperature and moisture effects. It summarises the design formulae and tables A1 to A6 provide calculated reinforcements required for control of thermal and shrinkage cracking. Part 2 provides calculations of crack widths in mature concrete under structural loading. It summarises the design formulae and tables B1 to B36 tabulate the service and ultimate flexural capacity of a range of slab thickness and reinforcement arrangements under differing conditions of crack width limitation, concrete strength and cover.

"Sinopsis" puede pertenecer a otra edición de este libro.

Reseña del editor

Concrete expands and then contracts because of the increase in temperature during hydration of cement and subsequent fall in temperature. In continuous structures, if this movement is restrained, tensile stresses will develop which can cause cracks to form. Although it is accepted that there will be cracks in reinforced concrete structures, the degree and magnitude of cracking should be controlled. In the design of liquid retaining structures, it is essential to restrict the width of cracks in structures. The maximum design surface crack widths (w) in BS8007 for direct tension and flexure or restrained temperature and moisture effects are as follows: w = 0.2 mm for severe or very severe exposure; and, w = 0.1 mm for critical aesthetic appearance.The design calculations of both the serviceability limit state of cracking due to thermal and moisture effects and flexural can be tedious and time consuming. In the preliminary design stage, the design tables in this document will assist and 'short-cut' the design process and therefore save valuable time. "Design tables to BS8007" has been divided into two parts. Part 1 provides calculations of minimum reinforcement, crack spacing, and crack widths in relation to temperature and moisture effects. It summarises the design formulae and tables A1 to A6 provide calculated reinforcements required for control of thermal and shrinkage cracking. Part 2 provides calculations of crack widths in mature concrete under structural loading. It summarises the design formulae and tables B1 to B36 tabulate the service and ultimate flexural capacity of a range of slab thickness and reinforcement arrangements under differing conditions of crack width limitation, concrete strength and cover.

"Sobre este título" puede pertenecer a otra edición de este libro.

  • EditorialThomas Telford Ltd
  • Año de publicación1996
  • ISBN 10 0727725173
  • ISBN 13 9780727725172
  • EncuadernaciónTapa blanda
  • IdiomaInglés
  • Número de páginas64
  • Contacto del fabricanteno disponible

Comprar usado

Condición: Como Nuevo
Like NewLIKE NEW
Ver este artículo

EUR 29,80 gastos de envío desde Reino Unido a España

Destinos, gastos y plazos de envío

Resultados de la búsqueda para Design Tables to Bs8007: Design of Concrete Structures...

Imagen de archivo

Cheng, Richard
Publicado por Thomas Telford, 1996
ISBN 10: 0727725173 ISBN 13: 9780727725172
Antiguo o usado Tapa dura

Librería: Mispah books, Redhill, SURRE, Reino Unido

Calificación del vendedor: 4 de 5 estrellas Valoración 4 estrellas, Más información sobre las valoraciones de los vendedores

Hardcover. Condición: Like New. Like NewLIKE NEW. book. Nº de ref. del artículo: ERICA83007277251733

Contactar al vendedor

Comprar usado

EUR 153,47
Convertir moneda
Gastos de envío: EUR 29,80
De Reino Unido a España
Destinos, gastos y plazos de envío

Cantidad disponible: 1 disponibles

Añadir al carrito