Excerpt from Simulating the Effect of Beamed Ceilings on Smoke Flow, Vol. 1: Comparison of Numerical and Experimental Results
A short beam spaced experiment, experiment 4, and a medium beam spaced experiment, experiment 16, were chosen for the comparisons in this report. The large beam spaced experiments, experiments 19, 20 and 21, required more grids to simulate two channels than the short and medium case which would have required more computer time. Experiment 4 consisted of ceiling beams spaced m (4 ft) apart with a depth of m (1 ft). Experiment 16 consisted of ceiling beams spaced m (8 ft) apart with a depth of m (2 ft). Numerical results predicted by a field model are shown to be in substantial agreement for these two experiments. Wood cribs with measured heat release rates were used as the fire source.
About the Publisher
Forgotten Books publishes hundreds of thousands of rare and classic books. Find more at www.forgottenbooks.com
This book is a reproduction of an important historical work. Forgotten Books uses state-of-the-art technology to digitally reconstruct the work, preserving the original format whilst repairing imperfections present in the aged copy. In rare cases, an imperfection in the original, such as a blemish or missing page, may be replicated in our edition. We do, however, repair the vast majority of imperfections successfully; any imperfections that remain are intentionally left to preserve the state of such historical works.
"Sinopsis" puede pertenecer a otra edición de este libro.
Excerpt from Simulating the Effect of Beamed Ceilings on Smoke Flow, Vol. 1: Comparison of Numerical and Experimental Results
A short beam spaced experiment, experiment 4, and a medium beam spaced experiment, experiment 16, were chosen for the comparisons in this report. The large beam spaced experiments, experiments 19, 20 and 21, required more grids to simulate two channels than the short and medium case which would have required more computer time. Experiment 4 consisted of ceiling beams spaced m (4 ft) apart with a depth of m (1 ft). Experiment 16 consisted of ceiling beams spaced m (8 ft) apart with a depth of m (2 ft). Numerical results predicted by a field model are shown to be in substantial agreement for these two experiments. Wood cribs with measured heat release rates were used as the fire source.
About the Publisher
Forgotten Books publishes hundreds of thousands of rare and classic books. Find more at www.forgottenbooks.com
This book is a reproduction of an important historical work. Forgotten Books uses state-of-the-art technology to digitally reconstruct the work, preserving the original format whilst repairing imperfections present in the aged copy. In rare cases, an imperfection in the original, such as a blemish or missing page, may be replicated in our edition. We do, however, repair the vast majority of imperfections successfully; any imperfections that remain are intentionally left to preserve the state of such historical works.
"Sobre este título" puede pertenecer a otra edición de este libro.
Sus derechos de garantía legal: Todos los consumidores de la UE se benefician de al menos dos años de protección de garantía legal para cualquier bien de consumo que se venda en la UE. Ver más
Librería: Forgotten Books, London, Reino Unido
Paperback. Condición: New. No Jacket. Print on Demand. Beamed ceilings and smoke flow explained through real?world tests This report compares a field model of smoke movement with laboratory experiments that use beams to shape the flow. It examines how temperature rises and drops travel through channels formed between beams, and how well the numerical predictions match measurements.The study focuses on two experiments with different beam depths and spacings. It describes grid setups near the floor and ceiling, the interpolation of instrument data, and how the model captures the main features of the plume and channeling. The author shows that the field model can predict the time history of temperature rise and the drop off across adjacent channels, with some locations near the fire presenting greater measurement sensitivity.How beams channel smoke and create distinct temperature patternsHow grid resolution and interpolation affect accuracy near the fireHow changing beam depth and spacing changes results between experimentsHow numerical and experimental data compare across multiple sensor locationsIdeal for readers of fire dynamics, ventilation modeling, and engineering simulations who want a practical look at validating field models against experiments. This book is a reproduction of an important historical work, digitally reconstructed using state-of-the-art technology to preserve the original format. In rare cases, an imperfection in the original, such as a blemish or missing page, may be replicated in the book. print-on-demand item. Nº de ref. del artículo: 9780366878178_0
Cantidad disponible: Más de 20 disponibles