"Sobre este título" puede pertenecer a otra edición de este libro.
Gastos de envío:
EUR 3,72
A Estados Unidos de America
Descripción Condición: New. Nº de ref. del artículo: ABLIING23Apr0316110134556
Descripción Condición: New. PRINT ON DEMAND Book; New; Fast Shipping from the UK. No. book. Nº de ref. del artículo: ria9783847310723_lsuk
Descripción PF. Condición: New. Nº de ref. del artículo: 6666-IUK-9783847310723
Descripción Taschenbuch. Condición: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -The Irish government, UK government and European Commission have recently passed a ban on the sale of all incandescent/GLS lamps above 100W, which commenced in September 2009 with smaller Wattages to be phased out by 2012. This paper sets out to investigate if CFLs are an adequate, suitable and appropriate replacement for GLS lamps in domestic environments. The main areas examined are power factor and total harmonic distortion, but other CFL characteristics are also investigated by means of literature review, to provide a complete overview of CFL performance. The measured power factor of all CFLs averaged 0.57 and ranged between 0.52 and 0.62. The effects of harmonic distortion on the current waveform of a CFL circuit was significant and reached levels up to 80% of the fundamental frequency. However, this large harmonic distortion is returned on the waveform of a smaller current than would be drawn by a GLS lamp and hence, effects on the national grid and risks of an overloaded three phase neutral conductor are less than sometimes claimed by researchers. 80 pp. Englisch. Nº de ref. del artículo: 9783847310723
Descripción PAP. Condición: New. New Book. Shipped from UK. THIS BOOK IS PRINTED ON DEMAND. Established seller since 2000. Nº de ref. del artículo: L0-9783847310723
Descripción Taschenbuch. Condición: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - The Irish government, UK government and European Commission have recently passed a ban on the sale of all incandescent/GLS lamps above 100W, which commenced in September 2009 with smaller Wattages to be phased out by 2012. This paper sets out to investigate if CFLs are an adequate, suitable and appropriate replacement for GLS lamps in domestic environments. The main areas examined are power factor and total harmonic distortion, but other CFL characteristics are also investigated by means of literature review, to provide a complete overview of CFL performance. The measured power factor of all CFLs averaged 0.57 and ranged between 0.52 and 0.62. The effects of harmonic distortion on the current waveform of a CFL circuit was significant and reached levels up to 80% of the fundamental frequency. However, this large harmonic distortion is returned on the waveform of a smaller current than would be drawn by a GLS lamp and hence, effects on the national grid and risks of an overloaded three phase neutral conductor are less than sometimes claimed by researchers. Nº de ref. del artículo: 9783847310723
Descripción PAP. Condición: New. New Book. Delivered from our UK warehouse in 4 to 14 business days. THIS BOOK IS PRINTED ON DEMAND. Established seller since 2000. Nº de ref. del artículo: L0-9783847310723
Descripción Condición: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Duff James ThomasJames Thomas Duff is a graduate of the School of Electrical Engineering Systems, Dublin Institute of Technology, Ireland. He is currently working for Arup Consulting Engineers in Dublin and has began a PhD, which wi. Nº de ref. del artículo: 5509202