"Sinopsis" puede pertenecer a otra edición de este libro.
"Sobre este título" puede pertenecer a otra edición de este libro.
Gastos de envío:
EUR 3,75
A Estados Unidos de America
Descripción Condición: New. Nº de ref. del artículo: ABLIING23Apr0316110135530
Descripción Condición: New. PRINT ON DEMAND Book; New; Fast Shipping from the UK. No. book. Nº de ref. del artículo: ria9783847324249_lsuk
Descripción Taschenbuch. Condición: Neu. This item is printed on demand - it takes 3-4 days longer - Neuware -Generally there are two different methods in calculating short-circuit currents in power system networks in terms of considering arc resistance in calculations, the first method is based on considering the value of the arc resistance as a constant value (usually 0.5 ) or neglecting this value. By introducing some formulae for the arc resistance like the Warrington formula which is one of the most well-known formulae, second method could be applied. Second method is based on considering the value of the arc resistance in short-circuit calculation. To calculate the short-circuit current in power system networks our model should be accurate enough, to have an accurate model in theses studies the value of the arc resistance should be considered. The problem here is the non-linear relationship between fault current and arc resistance. In this study by using ETAP software for fault analysis, Microsoft visual studio 2010 (C++) for the related iteration, short-circuit studies based on symmetrical components has been investigated on two different IEEE networks. Results show the efficiency of the arc resistance formula which has been used in this study in special range of fault currents. 132 pp. Englisch. Nº de ref. del artículo: 9783847324249
Descripción PAP. Condición: New. New Book. Shipped from UK. THIS BOOK IS PRINTED ON DEMAND. Established seller since 2000. Nº de ref. del artículo: L0-9783847324249
Descripción Taschenbuch. Condición: Neu. nach der Bestellung gedruckt Neuware - Printed after ordering - Generally there are two different methods in calculating short-circuit currents in power system networks in terms of considering arc resistance in calculations, the first method is based on considering the value of the arc resistance as a constant value (usually 0.5 ) or neglecting this value. By introducing some formulae for the arc resistance like the Warrington formula which is one of the most well-known formulae, second method could be applied. Second method is based on considering the value of the arc resistance in short-circuit calculation. To calculate the short-circuit current in power system networks our model should be accurate enough, to have an accurate model in theses studies the value of the arc resistance should be considered. The problem here is the non-linear relationship between fault current and arc resistance. In this study by using ETAP software for fault analysis, Microsoft visual studio 2010 (C++) for the related iteration, short-circuit studies based on symmetrical components has been investigated on two different IEEE networks. Results show the efficiency of the arc resistance formula which has been used in this study in special range of fault currents. Nº de ref. del artículo: 9783847324249
Descripción PAP. Condición: New. New Book. Delivered from our UK warehouse in 4 to 14 business days. THIS BOOK IS PRINTED ON DEMAND. Established seller since 2000. Nº de ref. del artículo: L0-9783847324249
Descripción Condición: New. Dieser Artikel ist ein Print on Demand Artikel und wird nach Ihrer Bestellung fuer Sie gedruckt. Autor/Autorin: Omidi HoumanHe received his bachelor degree in Azad University of Iran. He has finished his master in Electrical Engineering (Power) in Universiti Teknologi Malaysia (UTM). His area of scientific interests include power system contro. Nº de ref. del artículo: 5510112